@ -67,8 +67,22 @@ Stichpunkte für text:
- zu methodes: normally EGSnrc or fluka fed with source model based on measurements at end of linac, go next step and feed it with out put of simulation/model (for virtual diagnostics)/digital twin of beam from gun to end of linac. More information as not only beam size but also convergence information available (full 6 D phase space in principle). Furthermore, this allows to change accelerator settings and results are directly propagated to MC (monte carlo) simulation and further. - zu methodes: normally EGSnrc or fluka fed with source model based on measurements at end of linac, go next step and feed it with out put of simulation/model (for virtual diagnostics)/digital twin of beam from gun to end of linac. More information as not only beam size but also convergence information available (full 6 D phase space in principle). Furthermore, this allows to change accelerator settings and results are directly propagated to MC (monte carlo) simulation and further.
- THz/microwave as addition diagnostic for longitudinal structure of short electron package??? -> Zitat PRL von Johannes...?
- nicht nur bunchlängen zeug sondern auch zwei energien (5 und 50MeV?)
(Simulation Von dosis und so weil da bisher ja starke abweichung. Das eben verbessern durch bessere Grundlage der simulation da collective effects drin. Aber auch Effekte von kurzen pulsen besser abgebildet, da Vergleich mit messung systematisch....
Basierend auch auf den Erkenntnisen von dem uhd Ding, und weil gute Quelle zur Hand (flute).
Verschiedene längen test bar auch mit dann cstart...
Zusätzlich, zb Tests bed pixeldetektor, zb mögliche Strukturen und wie sie erhalten bleiben bei direkter Erzeugung in der gun... (laser vermutlich nicht bei klinischen Quellen)
Möglichkeit für input von medizin welche temporale und spatial Struktur den überhaupt sinnvoll ist
Damit die mediziner besser einschätzen können was sie brauchen an Stahl Struktur, muss simulation von darauffolgender dosis genau sein?
nicht nur bunch längen sondern auch energy unterschiede untersuchen
----------- -----------
TODO: TODO:
- CHECK OUT: Prof. Dr. Dr. Jürgen Debus / Prof. Dr. Ivan Peric Particle therapy beam monitoring with HV-CMOS sensors
https://www.heika-research.de/en/research/medical-technology-health-mth/particle-therapy-beam-monitoring-hv-cmos-sensors
- What about longitudinal modulation which is transformed in spatial modulation by fast sweep in the end? similar to TDC or split ring resonator? - What about longitudinal modulation which is transformed in spatial modulation by fast sweep in the end? similar to TDC or split ring resonator?
- or what about energy modulation which is transformed to spatial modulation by spectrometer bend? - or what about energy modulation which is transformed to spatial modulation by spectrometer bend?

Binary file not shown.

After

Width:  |  Height:  |  Size: 395 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 140 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 168 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 115 KiB

View file

@ -17,3 +17,8 @@ D = 2.5506MeV/166.54g = 0.015315 MeV/g = 2.4538 × 1012 J/kg.
--------- ---------
Microcalorimeters detect the temperature change of an absorber after an incoming particle has deposited its kinetic energy as heat. This operation principle provides considerable advantage over conventional detectors with respect to energy resolution, detection efficiency, energy threshold and radiation hardness. The detection of X-rays with microcalorimeters achieves a relative energy resolution of 13 ‰ in the energy regime of 1100 keV. Microcalorimeters detect the temperature change of an absorber after an incoming particle has deposited its kinetic energy as heat. This operation principle provides considerable advantage over conventional detectors with respect to energy resolution, detection efficiency, energy threshold and radiation hardness. The detection of X-rays with microcalorimeters achieves a relative energy resolution of 13 ‰ in the energy regime of 1100 keV.
-------------
In the KiT-RT solver, we are interested in the linear Boltzmann equation, where the particles dont interact with one another, only with the background material.
https://kit-rt.readthedocs.io/en/develop/physics.html